Over the years, “ELCEN” has produced various types of Motors.
Three Phase Motors (eff 2)
 

To meet the international standards and trends, "ELCEN" three phase motors are available in standard frames as attached in PDF below. Certain motors are also available in different frames.

 
Three Phase Motors (eff 1)
 
The ELCEN range of energy efficient motors from 0.37 Kw ( Frame 71) to 45 Kw ( Frame 225L). Use of these motors can lead to substantial reduction in energy costs. The payback periods are in the order of 3 to 6 months depending upon the usage. Even replacing existing motors with EE motors in power intensive industries gives paybacks within 1 to 2 years.
 
Brake Motors
 

"ELCEN" Brake motors are normally supplied with D.C. fail safe brakes. also known as normally ON brake. The motor is braked (Locked) when power is not applied i.e. de-energized to brake. This ensures real fail safe braking. The construction is quite robust and requires very limited maintenance. With wearing of liners on the rotor of brake, the air-gap has can be easily adjusted. If necessary. the rotor can be easily replaced completely as well. The brake is mounted on end covers on non-driving end of the motor. It comes with a Manual release lever.

 
Duel Speed motors
 

A variety of applications such as machine tools, fan and pumps, hoists and cranes, positioning equipment and many others need dual speed motars. Dual speeds can be achieved either by separate winding or by changing pale connections, By and large, by changing the speed, the output power of the motor changes but the torque remains almost constant. The best motor for the application can be selected from the table below, For quantity requirements special ratings can be developed.

 
Dual Voltage Motor
 

Full port design minimizes pressure losses and increases flow capacities thus reducing energy and pumping costs.

 
Inverter Duty Motors
 

Machine tools and process equipment can perform better if the speed of the prime mover can be controlled. This requirement leads to use of Variable Frequency Inverters or Drives, popularly known as VFDs in combination with the electric motors. It is advisable to use Inverted Rated motors while controlling the motor through VFDs. Invert Rated Insulation protects the motor from voltage spikes and surges generated while operating the motor with VFDs.

 
Torque Motors
 

Torque motors are special induction motors with specific stall torque and torque –speed characteristic curve. Torque Motors have high Slip Characteristic which can be smartly used in winder application, may it be plastic film or metallic wire.

 
Cooling Tower Motors
 

Cooling tower requires robust and efficient motors which “ELCEN” provides. Being higher ambient temperature, highly moist air and continuous operation needs special care. “ELCEN” cooling tower motors are quite efficient and protected to fight against moisture, i.e. painted for high moist environment, low temperature rise due to batter efficiency and IP 55 protected. More over the windings are protected against moisture as well. All put together, it is made for cooling tower for longer and efficient life. The special shaft diameters and lengths can be manufactured as per requirement.

 
Custom Built Motors
 

Use of custom built motors many times results in making the application much easier. cost competitive or maintenance free. "'ELCEN" has excelled in developing and manufacturing custom built motors. Motors with non standard flanges. shaft dimensions or mounting bases can be manufactured in economically attractive quantities. Different duty cycles at different speeds in dual speed motors OR different torque speed characteristic motors can be manufactured economically as well.